How is hip prosthesis and proximal femoral nail stability affected by lesser trochanter fractures: A comparative finite element analysis by lesser trochanter fractures: A comparative finite element analysis

Mehmet Nuri Konya, Ahmet Aslan, Sibel Bakbak

Issue: 2018, Volume 29 - Issue 2 Pages: 079-086 DOI: 10.5606/ehc.2018.58735
0 4197

Comparison of non-compression and compression interlocking intramedullary nailing in rabbit femoral shaft osteotomy model

Mehmet Emre Baki, Cengiz Aldemir, Fatih Duygun, Ali Doğan, Gökçen Kerimoğlu

Issue: 2017, Volume 28 - Issue 1 Pages: 007-012 DOI: 10.5606/ehc.2017.54333
0 4072

An extraordinary mechanism causing intraoperative migration of the Kirschner-wire

Mehmet Eroğlu, Özal Özcan, İhsan Şentürk, Mehmet Yücehan

Issue: 2016, Volume 27 - Issue 1 Pages: 058-060 DOI: 10.5606/ehc.2016.12
0 3586

Intrapelvic acetabulum surgery: does the positioning of the plate fixation play a role in the stability of the osteosynthesis?

Gergely Sztrinkai, Tamás Bodzay, Benjámin Madarász, Gergely Zoltán, Tamás Gál, Károly Váradi

Issue: 2015, Volume 26 - Issue 3 Pages: 126-130 DOI: 10.5606/ehc.2015.27
0 3832

Does surgically fixation of pubic fracture increase the stability of the operated posterior pelvis?

Tamás Bodzay, Gergely Sztrinkai, Sándor Pajor, Tamás Gál, Zoltán Jónás, Péter Erdös, Károly Váradi

Issue: 2014, Volume 25 - Issue 2 Pages: 091-095 DOI: 10.5606/ehc.2014.20
0 4255

Further development of our finite element pelvic model to compare fixation methods for pelvic fractures

Gergely Sztrinkai, Tamás Bodzay, Sándor Pajor, Péter Erdös, Zsolt Vendégh, Zoltán Jónás, Károly Váradi

Issue: 2014, Volume 25 - Issue 1 Pages: 008-014 DOI: 10.5606/ehc.2014.03
0 3941

Determination of the effect on the proximal femoral load distribution of diaphyseal cement support in femoral intertrochanteric fractures with calcar defect by finite element analysis

Hakan Çift, Serdar Deniz, Fatih Ekşioğlu

Issue: 2013, Volume 24 - Issue 3 Pages: 163-168 DOI: 10.5606/ehc.2013.35
0 4848

Single versus double screw fixation for the treatment of scaphoid waist fractures: Finite element analysis and preliminary clinical results in scaphoid nonunion

Baver Acar, Özkan Köse, Adil Turan, Yusuf Alper Katı, Ferhat Güler

Issue: 2020, Volume 31 - Issue 1 Pages: 073-080 DOI: 10.5606/ehc.2020.71521
2902 5135

Evaluation of stabilization methods of pelvic ring injuries by finite element modeling

Tamás Bodzay, Tamás Burján, Cecília Bagdi, István Flóris, Zsolt Vendégh, Károly Váradi

Issue: 2007, Volume 18 - Issue 3 Pages: 108-115
0 2869

A NEW FORCEPS FOR BENDING KIRSCHNER WIRES: TECHNICAL NOTE

Burak TUNA

Issue: 2001, Volume 12 - Issue 2 Pages: 218-219
0 2430

Suture anchor fixation may be an alternative to tension band wiring in olecranon fractures: Finite element analysis

Tolgahan Kuru, İbrahim Mutlu

Issue: 2020, Volume 31 - Issue 2 Pages: 238-245 DOI: 10.5606/ehc.2020.73586
3425 3945

Comparison of clinical and radiological results of fixation methods with retrograde intramedullary Kirschner wire and plate-screw in extra-articular metacarpal fractures

Mehmet Baydar, Abdurrahman Aydın, Ayşe Şencan, Osman Orman, Serkan Aykut, Kahraman Öztürk

Issue: 2021, Volume 32 - Issue 2 Pages: 397-405 DOI: 10.52312/jdrs.2021.40
4596 2113

The importance of Böhler’s angle in calcaneus geometry: A finite element model study

Alper Gültekin, Erdinç Acar, Levent Uğur, Aytaç Yıldız, Ulaş Serarslan

Issue: 2021, Volume 32 - Issue 2 Pages: 420-427 DOI: 10.52312/jdrs.2021.81251
3551 2306

Traction therapy in lumbar disc hernias: A finite element analysis study

Erol Öten, Osman Civan, Levent Uğur

Issue: 2022, Volume 33 - Issue 1 Pages: 086-092 DOI: 10.52312/jdrs.2022.516
7131 1740

Comparative finite element analysis of four different internal fixation implants for Pauwels type III femoral neck fractures in various fracture angles in the sagittal plane

Alaettin Özer, Kerim Öner, Ahmet Emin Okutan, Muhammet Salih Ayas

Issue: 2022, Volume 33 - Issue 2 Pages: 352-358 DOI: 10.52312/jdrs.2022.676
2943 1915

Can a coracoclavicular screw added to the clavicular hook plate reduce subacromial stress? A finite element analysis

Mert Kumbaracı, Alaettin Özer, Muhammet Bozoğlan, Ali Turgut

Issue: 2022, Volume 33 - Issue 3 Pages: 609-615 DOI: 10.52312/jdrs.2022.837
1970 1580

Comparison of different internal fixation implants in the treatment of talar neck fractures: A finite element analysis

Xin Fu, Hong-Bin Cao, Nan Li, Gui-Xin Wang, Jin-Quan He

Issue: 2024, Volume 35 - Issue 1 Pages: 027-035 DOI: 10.52312/jdrs.2023.1280
2164 2286

Quantitative analysis of protective Kirschner wire diameters in lateral opening wedge distal femoral osteotomy: A finite element study

Alican Baris, Emre Özmen, Esra Circi, Serdar Yuksel, Ozan Beytemür

Issue: 2025, Volume 36 - Issue 1 Pages: 097-106 DOI: 10.52312/jdrs.2025.1806
1598 1248

Enhanced scaphoid fixation with Kirschner wire: A clinical and finite element study

İbrahim Halil Dadir, Enejd Veizi, Uğur Bezirgan, Mustafa Bilgiç, Şahin Çepni, Erdinç Acar

Issue: 2026, Volume 37 - Issue 1 Pages: 170-179 DOI: 10.52312/jdrs.2026.2414
340 1155

In case effects of proximal fibular osteotomy and total knee arthroplasty on load distribution in the human knee: A comparative finite element study

Bünyamin Ari, Melih Canlidinç, Nafiz Yaşar, Mehmet Ali Gedik

Issue: 2026, Volume 37 - Issue 1 Pages: 180-189 DOI: 10.52312/jdrs.2026.2455
380 848