Reversed Z-effect and Z-effect phenomena in femoral neck fracture treated with a dynamic locking plate fixation: Case report

Radoslav Morochovič, Miloš Kňazovický, Martin Paulo, Katarína Takáčová, Rastislav Burda

Issue: 2021, Volume 32 - Issue 1 Pages: 249-252 DOI: 10.5606/ehc.2021.77186
2070 3859

May minimally invasive plate osteosynthesis be an alternative to intramedullary nailing in selected spiral oblique and spiral wedge tibial shaft fractures?

Yusuf Alper Katı, Özdamar Fuad Öken, Ahmet Özgür Yıldırım, Özkan Köse, Melih Ünal

Issue: 2020, Volume 31 - Issue 3 Pages: 494-501 DOI: 10.5606/ehc.2020.75052
1344 2327

Pediatric tibial shaft and distal metaphyseal fractures

Osman Civan, Bahadır Alimoğlu, Mustafa İçen, Selim Taşkın, Ali Cavit, Yetkin Söyüncü, Mustafa Ürgüden

Issue: 2020, Volume 31 - Issue 3 Pages: 532-540 DOI: 10.5606/ehc.2020.75764
1322 3153

Rare isolated coracoid mid-process fracture with displacement in an adolescent: Case report

Bülent Güneri, Murat Üzel

Issue: 2020, Volume 31 - Issue 3 Pages: 630-633 DOI: 10.5606/ehc.2020.72842
1252 2102

The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis

Serhat Durusoy, Kerim Öner, Alaattin Özer, Hüseyin Fatih Sevinç

Issue: 2021, Volume 32 - Issue 1 Pages: 075-084 DOI: 10.5606/ehc.2021.77279
1204 2388

Reliability of radiographic union scale in tibial fractures and modified radiographic union scale in tibial fractures scores in the evaluation of pediatric forearm fracture union

Turan Bilge Kizkapan, Abdulhamit Misir, Sinan Oguzkaya, Mustafa Ozcamdalli, Erdal Uzun, Gokhan Sayer

Issue: 2021, Volume 32 - Issue 1 Pages: 185-191 DOI: 10.5606/ehc.2021.78465
1039 2186

Comparison of two different screw trajectories in the treatment of oblique scaphoid fractures: A mechanical study on composite bone models

Bülent Kılıç, Mustafa Çalışkan, Anıl Agar, Bora Uzun, Fatih Ertem, Deniz Gülabi, Cemil Ertürk

Issue: 2021, Volume 32 - Issue 2 Pages: 377-382 DOI: 10.52312/jdrs.2021.15
1569 1210

Common musculoskeletal disorders in chronic liver disease patients

Rajat Ranjan, Sanjiv Rampal, Ashish Jaiman, Mehmet Ali Tokgöz, Jun Kit Koong, Kamarajan Ramayah, Ruveena Rajaram

Issue: 2021, Volume 32 - Issue 3 Pages: 818-823 DOI: 10.52312/jdrs.2021.25
2693 2886

The role of arthroscopy in the diagnosis of concomitant soft tissue injuries in scaphoid fractures and the effect of concomitant soft tissue injuries and fracture comminution on outcomes: A case-control study

Ali Özdemir, Anıl Pulatkan, Ebubekir Eravsar, Mehmet Ali Acar

Issue: 2021, Volume 32 - Issue 3 Pages: 729-735 DOI: 10.52312/jdrs.2021.309
1853 1318

Mortality rates of hip fracture patients with non-operative treatment

Joonha Lee, Keun-Young Shin, Hyun-Wook Nam, Minyoung Oh, Gi Sung Shim

Issue: 2022, Volume 33 - Issue 1 Pages: 017-023 DOI: 10.52312/jdrs.2022.495
2136 1352

Bisphosphonate therapy associated with bilateral atypical femoral fracture and delayed union

István Gárgyán, Dávid Dózsai, István Csonka, Ferenc Rárosi, Tamás Bodzay, Ákos Csonka

Issue: 2022, Volume 33 - Issue 1 Pages: 024-032 DOI: 10.52312/jdrs.2022.355
1476 1302

Arthroscopic revision of osteochondral autograft in distal tibia: A case report demonstrating precision of intraoperative 3D fluoroscopy

Ronny Lopes, Teodor Negru, Alexandre Hardy, Hasan Basri Sezer

Issue: 2022, Volume 33 - Issue 1 Pages: 238-244 DOI: 10.52312/jdrs.2022.431
1158 1063

Dynamic hip screw versus intramedullary nailing for the treatment of A1 intertrochanteric fractures: A retrospective, comparative study and cost analysis

Mattia Alessio-Mazzola, Giacomo Traverso, Francesco Coccarello, Francesca Sanguineti,Matteo Formica

Issue: 2022, Volume 33 - Issue 2 Pages: 314-322 DOI: 10.52312/jdrs.2022.646
3502 1400

The evaluation of a de novo biplanar distal humerus plate: A biomechanical study

Nihat Acar, Ahmet Karakaşlı, Onur Gürsan, R. Buğra Hüsemoğlu

Issue: 2022, Volume 33 - Issue 2 Pages: 345-351 DOI: 10.52312/jdrs.2022.604
1031 951

Comparative finite element analysis of four different internal fixation implants for Pauwels type III femoral neck fractures in various fracture angles in the sagittal plane

Alaettin Özer, Kerim Öner, Ahmet Emin Okutan, Muhammet Salih Ayas

Issue: 2022, Volume 33 - Issue 2 Pages: 352-358 DOI: 10.52312/jdrs.2022.676
1742 1180

Fixation of bilateral acetabular fractures using the modified Stoppa approach: Two-year clinical outcomes

Fatih İlker Can, Rabia Mihriban Kılınç, Emre Gültaç, Cem Yalın Kılınç, İsmail Gökhan Şahin

Issue: 2022, Volume 33 - Issue 3 Pages: 624-630 DOI: 10.52312/jdrs.2022.858
1059 908

Functional and radiological outcomes of dynamic hip screw with trochanteric stabilizing plate versus short proximal femoral nail in management of unstable trochanteric fractures: A randomized-controlled trial

Elsayed Kassem, Ramy Younan, Mina Abaskhron, Mohamed Abo-Elsoud

Issue: 2022, Volume 33 - Issue 3 Pages: 531-537 DOI: 10.52312/jdrs.2022.800
963 757

Is microsurgical experience essential in Zone II flexor tendon injuries?

Çağdaş Pamuk

Issue: 2023, Volume 34 - Issue 1 Pages: 183-189 DOI: 10.52312/jdrs.2023.931
1200 871

Comparison between unilateral curved and bilateral straight percutaneous vertebral augmentation in the treatment of osteoporotic vertebral compression fractures: A meta-analysis

Xin Fu*, Yao-min Li*, Peng Tian, Gui-jun Xu, Zhi-jun Li

Issue: 2023, Volume 34 - Issue 2 Pages: 237-244 DOI: 10.52312/jdrs.2023.967
941 1268

Does skyline view prevent extensor tendon pathologies during volar plating of distal radius? An ultrasonographic evaluation

Sinan Yüksel, Ali Nazmican Güröz, Alper Öztürk, Yenel Gürkan Bilgetekin, Önder Ersan, Arda Halil Ceylan

Issue: 2023, Volume 34 - Issue 2 Pages: 331-337 DOI: 10.52312/jdrs.2023.738
750 1036